Product Details:
Payment & Shipping Terms:
|
Other Name: | Omnidirectional Electret Condenser Microphone | S/N Ratio: | ≥58dB |
---|---|---|---|
Sound Level: | 110dB | Directivity: | Omni-directional |
Storage Temperature: | -30~+70℃ | Operating Temperature: | -20~+60℃ |
Highlight: | smd chip resistor,electret condenser microphone |
Electret condenser microphone inserts 6050 6*5mm with PCB pins
Storage and judgement conditions:
Temperature range(℃) | Rel Humidity(%) | Static pressure(kPa) | |
Judgement | 19~21 | 60~70 | 86~106 |
Storage | -30~70 | ||
Operating | -20~60 |
Specifications:
Test conditions: Vs=4.5V, RL=2.2KΩ, Temp=20±2℃, R.H=60±5%
Item | Symbol | Test conditions | Min. | Standard | Max. | Unit |
Sensitivity | S |
f=1KHz, S.P.L=1Pa |
-43 | -40 | -37 |
dB 0dB=1V/Pa |
Impedance | Z |
f=1KHz, S.P.L=1Pa |
2.2 | KΩ | ||
Directivity | Omni-directional | |||||
Current consumption | I | 50 | 500 | μA | ||
Operation voltage range | Vs | 1.0 | 4.5 | 10 | V | |
S/N ratio | S/N(A) |
f=1KHz, S.P.L=1Pa A curve |
≥58 | dB | ||
Decreacing voltage characteristic | △S |
f=1KHz, S.P.L=1Pa Vs=4.5-3.0V |
-3 | dB | ||
Max. input sound level | MISPL |
f=1KHz Distortion<3% |
110 | dB |
Frequency response:
Test circuit:
Measurement Circuit
Vs:Source Voltage 4.5V RL:Load Resistance 2.2KΩ
Test setup drawing:
Reliability Test:
All tests should be done after 2 hours of conditioning at 20℃,R.H65% ,while the sensitivity is to be within ±3dB from the initial sensitivity after the following experiments.
8.1 High Temperature Test
High temperature: +80℃
Duration: 72 hours
8.2 Low Temperature Test
Low temperature: -40℃
Duration: 72 hours
8.3 Temperature Cycle Test (See in Fig.1)
Low temperature: -40℃
High temperature: +80℃
Changeover time: 10min
Duration: 30min
Cycle: 32
8.4 Statical Humidity Test
Temperature: +40℃
Relative humidity: 90~95%
Duration: 72hours
8.5 Vibration Test
Amplitude : 1.52mm
Duration: 1minutes /plane
Freq.range: 10~55 Hz
Total time: 2 hours
8.6 Dropping Test
Drop a unit unpacked onto a board of 20mm thick.
Height: 1.0 m
Cycle: 6
Regarding the Soldering operation
a. Use 25~ 30W soldering iron and maintain 310℃~330℃ in operation.
b. Operators who work in the solder fixture and the soldering iron must be statically grounded
under each soldering process.
c. Soldering should be accomplished within two seconds at each terminal so as not to be overheated.
d . Optimal design for heat sink pad is same as below.
Dimension:(mm)
Contact Person: Mr. Roy Zhang
Tel: 86 574 55878090
Fax: 86-574-55878097