Product Details:
Payment & Shipping Terms:
|
Other Name: | Small Signal Relay | Contact Ratings: | 2A 120VAC/24VDC |
---|---|---|---|
Max.switching Voltage: | 120VAC/60VDC | Max.switching Current: | 2A |
Max.switching Power: | 240VA/48W | Initial Contact Resistance: | 100mΩMax At 6VDC 1A |
Life Expectancy Electrical: | 100,000 Operations(rated Load) | Contact Material: | Au+Ag Alloy |
High Light: | automotive starter relay,miniature signal relay |
Miniature signal relay 23F(OMRON G5V-1) SPDT 2A 120VAC, 12.5*7.5*10mm
Description:
A relay is an electrically operated switch. Many relays use an electromagnet to mechanically operate a switch, but other operating principles are also used, such as solid-state relays. Relays are used where it is necessary to control a circuit by a low-power signal (with complete electrical isolation between control and controlled circuits), or where several circuits must be controlled by one signal.
Single Pole Double Throw (SPDT):
Such relay consists of a pair of coil pins, a common pin, a normally open (NO) pin and a normally closed (NC) pin. When the relay is not activated, the common pin is in contact with the NC pin and when it is activated, the common pin will break away from contact with the NC pin and subsequently makes contact with the NO pin. Also, when the relay is deactivated (from activated state), the common pin will conversely break away from contact with the NO pin and return back in contact with the NC pin.
Features:
• Low coil power consumption
• High sensitivity.
• Small size, light weight.
• PC board mounting.
Applications:
Suitable for automation facilities, telecommunication equipment, wireless radio remote control, sound control toys application etc.
General data:
Contact form |
1C(1Z)-SPDT |
Insulation resistance | 100MΩMin at500VDC |
Dielectric strength between open contacts | 500VAC 50-60HZ(1 minute) |
Dielectric strength between contacts and coil | 1000VAC 50-60HZ(1 minute) |
Operate time | 5ms max. |
Release time | 5ms max. |
Ambient temperature | -30°C ~ +70°C |
Shock resistance-Malfuction | 10G |
Shock resistance-Destruction | 15G |
Vibration resistance | 10-55Hz,1.5mm double amplitude |
Ambient humidity | 40-85% RH |
Weight | Approx 1.8g |
Coil data (@20°C)
Rated voltage (VDC) |
Coil Resistance Ω(±10%) |
Max Operate Voltage (VDC) | Min Release Voltage (VDC) | Max Applied Voltage (VDC) | |
0.15W | 0.2W | ||||
3 | 60 | 45 | 2.4 | 0.15 | 3.9 |
5 | 167 | 125 | 4 | 0.25 | 6.5 |
6 | 240 | 180 | 4.8 | 0.3 | 7.8 |
9 | 540 | 405 | 7.2 | 0.45 | 11.7 |
12 | 960 | 720 | 9.6 | 0.6 | 15.6 |
24 | 3840 | 2880 | 19.2 | 1.2 | 31.2 |
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
3.Unless otherwise stated, the rated coil voltage specified in coil parameter tableshall be used for all tests and its application to the relay
Outline dimension(mm):
PCB board layout and Wiring diagram:
Contact Person: Mr. Roy Zhang
Tel: 86 574 56807757
Fax: 86-574-55844980