Other Name: | Auto Start Relay | Contact Ratings: | 20A 14VDC |
---|---|---|---|
Max.switching Voltage: | 16VDC/120VAC | Max.switching Current: | 25A |
Max.switching Power: | 840VA/400W | Initial Contact Resistance: | 100mΩMax At 6VDC 1A |
Life Expectancy Electrical: | 100,000 Operations(rated Load) | Contact Material: | Ag Alloy |
High Light: | electromagnetic power relay,automotive starter relay |
Mini auto relay T78, 15.7*12.3*14mm starter relay, Fuel pump relay
Description:
Relay is an electromagnetic device which is used to isolate two circuits electrically and connect them magnetically. They are very useful devices and allow one circuit to switch another one while they are completely separate. They are often used to interface an electronic circuit (working at a low voltage) to an electrical circuit which works at very high voltage. For example, a relay can make a 5V DC battery circuit to switch a 230V AC mains circuit. Thus a small sensor circuit can drive, say, a fan or an electric bulb.
What do SPST,SPDT,DPST and DPDT mean?
SP and DP refer to single pole and double pole, ST and DT refer to single throw and double throw.
Pole refers to the number of circuits controlled by the switch:SP switches control only one electrical circuit. DP switches control two independent circuits(and act like two identical switches that are mechanically linked). Don't confuse "pole" with "terminal". The DPST switch, for example, has four terminals, but it is a DP, not a 4P switch.
Throw refers to the extreme position of the actuator: ST switches close a circuit at only one position. The other position of the handle is OFF. DT switches close a circuit in the UP position, as well as the Down position(ON-ON). A DT switch can also have a center position(frequently ON-OFF-ON).
Single pole/throw and double pole/throw switches are by far the most common switches, but tripe and quadruple configurations are also available. They are commonly denoted 3PST,3PDT,4PDT, etc.
Applications:
Suitable for household electrical appliances, automation system, electronic equipment, instrument, meter, telecommunication facilities and remote control facilities.
General data:
Contact form |
1A(1H)-SPST NO 1B-SPST NC 1C(1Z)-SPDT |
Insulation resistance | 100MΩMin at500VDC |
Dielectric strength between open contacts | 500VAC 50-60HZ(1 minute) |
Dielectric strength between contacts and coil | 500VAC 50-60HZ(1 minute) |
Operate time | 10ms max. |
Release time | 5ms max. |
Ambient temperature | -40°C ~ +85°C |
Shock resistance-Malfuction | 10G |
Shock resistance-Destruction | 100G |
Vibration resistance | 10-55Hz,1.5mm double amplitude |
Ambient humidity | 40-85% RH |
Weight | Approx 6g |
Safety standard | UL |
Coil data (@20°C)
Rated voltage (VDC) |
Coil Resistance Ω(±10%) | Max Operate Voltage (VDC) | Min Release Voltage (VDC) | Max Applied Voltage (VDC) | |||
0.6W |
0.8W |
||||||
6 | 60 | 45 | 3.9 | 0.6 | 7.8 | ||
9 | 135 | 101 | 5.85 | 0.9 | 11.7 | ||
12 | 240 | 180 | 7.8 | 1.2 | 15.6 | ||
24 | 960 | 720 | 15.6 | 2.4 | 31.2 |